Residential Heating and Cooling Equipment Eligibility
Review the Residential Heating and Cooling Program Requirements prior to installing any equipment. Residential Heating and Cooling Program Requirements | Focus on Energy Terms and Conditions

Residential Heating and Cooling Incentives Eligibility Requirements

Furnace

Natural Gas Furnace 95%+ AFUE

  • Must be a customer of a participating electric utility and a participating natural gas utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Customer must use natural gas for home heating.
  • Furnace must have an annual fuel utilization efficiency (AFUE) of 95 percent or greater.
  • Furnace must meet ENERGY STAR® requirements for U.S. North gas furnaces.
  • Only natural gas furnaces are eligible.
  • Furnace must be a sealed combustion unit and must be the primary heating source for the home's living space.
  • Chimney liners must be installed where a high-efficiency gas furnace replaces an atmospherically-drafted furnace and only a water heater remains vented through the chimney. The interior opening left by the removed furnace must be closed with a metal cap and sealed with caulk or mortar.
  • Be sure to check our pre-qualified equipment lists at focusonenergy.com/heatingandcooling

Be sure to review the general program terms here before installing your equipment.

Boiler

Modulating Natural Gas Boiler 90%+ AFUE

  • Must be a customer of a participating natural gas utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Boiler must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
  • Boiler must include an outdoor-air reset control (integrated).
  • Boiler must have an input capacity less than 300 MBH (Thousand British Thermal Units per Hour).
  • Boiler must be sealed combustion unit.
  • Only natural gas boilers are eligible.
  • Boiler must be the primary heating source for the home's living space.
  • Chimney liners must be installed where a high-efficiency gas boiler replaces an atmospherically-drafted boiler and only a water heater remains vented through the chimney. The interior opening left by the removed boiler must be closed with a metal cap and sealed with caulk or mortar.
  • Be sure to check our pre-qualified equipment lists at focusonenergy.com/heatingandcooling
  • Boiler must meet ENERGY STAR® requirements.

Be sure to review the general program terms here before installing your equipment.

Smart Thermostat

  • Must be a customer of a participating electric utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Home heating source must be provided by a participating utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Smart thermostat must be installed on a furnace, boiler, or air source heat pump.
  • Does not qualify if installed on a water heater or ground source heat pump (geothermal).
  • Eligible models must be selected from the Focus on Energy qualified product list available at focusonenergy.com/smart.
  • Thermostat must be certified as an ENERGY STAR® Connected Thermostat, or meet the following requirements:
    • Must be Wi-Fi capable.
    • Must be capable of internet connection.
    • Must feature occupancy sensing, via geolocation and/or motion sensing.
    • The above features must be built-in and not require add-on devices or services.
    • The application and connectivity service must be free after thermostat purchase.
    • Thermostat default behavior must be to set back temperature when house is unoccupied
  • Smart thermostat must be installed to use with the home's primary heating source for the home's living space.
  • Only homes heated by a natural gas furnace, natural gas boiler or an air source heat pump are eligible for the smart thermostat incentive.
  • Smart thermostat must replace an existing thermostat that does not qualify for program incentives.
  • The customer must establish the Wi-Fi connection for program-qualified smart thermostats.
  • Be sure to check our pre-qualified equipment lists at focusonenergy.com/heatingandcooling

Combination Boiler

Modulating Combination Natural Gas Boiler with Integrated Domestic Hot Water and Outdoor Reset Control, 90%+ AFUE

    • Must be a customer of a participating natural gas utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
    • Boiler must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
    • Boiler must include an outdoor-air resent control (integrated).
    • Boiler must have an input capacity less than 300 MBH (Thousand British Thermal Units per Hour).
    • Boiler must be sealed combustion unit.
    • Boilers must also be the primary heating and domestic water heating source for the home.
    • Only natural gas boilers are eligible.
    • Chimney liners must be installed where a high-efficiency gas boiler replaces an atmospherically-drafted boiler and only a water heater remains vented through the chimney. The interior opening left by the removed boiler must be closed with a metal cap and sealed with caulk or mortar.
    • Be sure to check our pre-qualified equipment lists at focusonenergy.com/heatingandcooling
    • Boiler must meet ENERGY STAR® requirements.

Electronically Commutated Motor (ECM)

ECM Replacement

  • Must be a customer of a participating electric utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Must replace a permanent split capacitor (PSC) blower motor in an existing furnace or air handler.
  • Existing furnace must have an annual fuel utilization efficiency (AFUE) of 90 percent or greater.
  • Existing furnace must be a sealed combustion unit.
  • Furnace must be the primary heating source for the home's living space.
  • Be sure to check our pre-qualified equipment lists at focusonenergy.com/heatingandcooling

Dual Fuel Heat Pump

  • Must be a customer of a participating electric utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Air source heat pump with a minimum of 15 seasonal energy efficiency ratio (SEER) and a minimum of 8.5+ heating seasonal performance factor (HSPF) in region IV.
  • SEER and HSPF based on AHRI database, found at ahridirectory.org, for furnace, coil, and condenser.
  • System must be listed as "Heat Pumps" within AHRI, "Variable-Speed Mini-Split and Multi-Split Heat Pumps" and "Water-Source Heat Pumps" are not eligible.
  • Coil and condenser must be purchased and installed at the same time.
  • You cannot receive the incentive for both furnace and the Dual Fuel Heat Pump.
  • Furnace must be LP, oil, or electric fired (natural gas furnaces are not eligible).
  • Must be primary heating source for the home's living space.

Dual Fuel Heat Pump (Air Source Heat Pump with New or Existing Natural Gas Furnace)

  • Must be a customer of a participating electric utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Must be a customer of a participating natural gas utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Air source heat pump with a minimum of 15 seasonal energy efficiency ratio (SEER) and a minimum of 8.5+ heating seasonal performance factor (HSPF) in region IV.
  • SEER and HSPF based on AHRI database, found at ahridirectory.org, for furnace, coil, and condenser.
  • System must be listed as "Heat Pumps" within AHRI, "Variable-Speed Mini-Split and Multi-Split Heat Pumps" and "Water-Source Heat Pumps" are not eligible.
  • Coil and condenser must be purchased and installed at the same time.
  • You cannot receive the incentive for both furnace and the Dual Fuel Heat Pump.
  • Furnace must be natural gas fired (LP, oil, or electric furnaces are not eligible).
  • Must be primary heating source for the home's living space.

Indirect Water Heater

Indirect Water Heater for Home Heating Boiler

Single Package Vertical Unit

  • Must be a customer of a participating electric utility and a participating natural gas utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Single package vertical unit must meet the minimum efficiency requirements listed.
    • > 90%+ Thermal Efficiency, NG, > 10.0 EER Cooling
    • > 90%+ Thermal Efficiency, NG
  • Efficiency ratings will be verified using the AHRI database.
  • Required features must be documented on a specification sheet.

Package Terminal Heat Pump (PTHP)

  • Must be a customer of a participating electric utility. Verify your utility here: https://focusonenergy.com/about/participating-utilities.
  • Unit must be AHRI listed as a Commercial PTHP.
  • Must replace a Packaged Terminal Air Conditioner (PTAC). Replacement of existing PTHP does NOT qualify.
  • Window and through-the-wall air conditioners/heat pumps do not qualify.
  • The equipment size category (BTUh) is the cooling capacity value of the unit.
  • Must meet both heating and cooling specifications for the equipment size category.
    • < 8,000 BTUh, > 10.7 EER and > 3.1 COP
    • 8,000 - 9,999 BTUh, > 10.4 EER and > 3.0 COP
    • 10,000 - 12,999 BTUh, > 9.9 EER and > 2.9 COP
    • > 13,000 BTUh, > 9.3 EER and > 2.9 COP
  • All efficiency ratings will be verified using the AHRI database.